Turbmet

Turb Met PDF  Technical Specs
PDF Turb Met  Catalogue Page
 


Turbine Digital Meter     Suitable for Transferring DIESELSuitable for Transferring WATERSuitable for Transferring CHEMICALS

Simple, reliable, small, economical.
These meters are easily to install either in line or at the end of the delivery hose and are provided with an easy to read compact display. It is possible to install the meter directly on the nozzle and you can forget about straining to see readout several metres away. A rugged housing and sealed electronic board provide durable use in almost any conditions.
Two batteries easy to replace power the small microprocessor for a long time.

Performances

. Accuracy +/- 3% within the flow rate range
. Repeatability 0.5 %
. Operating temperature range -10 / 50 °C
. Pressure drop < 0.15 bar at 100 l/min
. Battery life 3 years

Water version
Nylon housing.
Calibrated at the factory to measure water.

Fuel version
Aluminium housing.
Calibrated at the factory to measure diesel fuel.

 



Turb inox

PDFs  Technical Specs
PDF  Catalogue Page
 


Turbine Digital Meter     Suitable for Transferring DIESELSuitable for Transferring UREASuitable for Transferring WATERSuitable for Transferring WINDSCREEN fluid

This series of stainless steel flow meters is designed to measure the widest possible range of fluids, including particulary chemically aggressive fluids. They are available in pulser versions and with remote displays. Thanks to a stainless steel casing it can be used in practically all conditions. The microprocessor is powered by two standard, easily replaced batteries for approximately 3 years life. Easy installation.

Performance

. Flow rate up to 100 l/min
. High precision up to +/- 1%
. Pulser version available, also with 90° inlet/outlet
. Flow rate indication: Partial 4 figures, total 8 figures
. PULSE OUT displays up to 100 litre pulses
. Working pressure 30 bar

 



K24

K24 Technical  Technical Specs
PDF Icons  Catalogue Page
 


K24 Inline Turbine Meter     Suitable for Transferring DIESELSuitable for Transferring WINDSCREEN fluidSuitable for Transferring UREASuitable for Transferring WATER

Simple, reliable and economic the three important characteristics of this digital meter, equipped with an easy to read compact screen. K24 is easy to install directly onto the nozzle or inline, or at the end of the delivery pipe. Thanks to a strong casing and a sealed electronic card it can be used in practically all conditions. The microprocessor is powered by two standard easily replaced batteries for approximately 3 years.

Performance

. Flow rate up to 100 l/min
. Precision +/- 1%
. Flow rate indication: Partial 4 figures, total 8 figures
. Inlet/outlet 1" Gas, male
. Working Pressure 10 bar

 



K24 Pulse

K24 PDF  Technical Specs
 


K24 Inline Pulse Meter     Suitable for Transferring DIESELSuitable for Transferring WINDSCREEN fluidSuitable for Transferring UREASuitable for Transferring WATER

Simple, reliable and economic, the three important characteristics of this pulse meter. Thanks to a strong casing and a sealed electronic card it can be used in practically all conditions with low viscosity fluid.

Performance

. Flow rate up to 100 l/min
. Precision +/- 1%
. Inlet/outlet 1" Gas
. Available in MxF and FxF
. Working Pressure 10 bar
. Max Current 100mA
. Max Voltage 28v
. IP65
. Working Pressure 10 bar

 



K200

K200 Pdf  Technical Specs
K200 Pdf  Catalogue Page
 


K200 Inline Oval Gear Meter     Suitable for Transferring DIESELSuitable for Transferring OILSuitable for Transferring GREASESuitable for Transferring WINDSCREEN fluid

The electronic oval gear meters for product delivery control and measurement are used in the private distribution of low, medium and high viscosity fluids such as fuel, lubrication oil and other special fluids compatible with the construction materials. The oval gear measuring principle adopted offers high precision and low pressure losses together with a compact lightweight design and easy installation. An electronic card with microprocessor permits control of the display and calibration of the meter. A complete range of models is designed to satisfy all flow rate requirements. Ease of use, compactness and the independent battery power supply make these products suitable for installation in both stationary systems on fluid transfer and distribution lines and in mobile applications as an accessory for delivery valves and guns and for all other industrial applications that require fluid delivery control.

Performance

. Precision ± 0.5 % in flow rate range after calibration
. Repeatibility 0.2%
. Pressure loss < 0.5 bars (7 psi) at max flow rate

 


K200p

k200p PDF  Technical Specs
K200p PDF  Catalogue Page
 


K200 Pulse Meter     Suitable for Transferring DIESELSuitable for Transferring OILSuitable for Transferring GREASESuitable for Transferring WINDSCREEN fluid

The oval gear pulse meters are designed to meet a wide range of product delivery measuring requirements in the private distribution of fuel, lubricant and low, medium and high viscosity liquids. The oval gear measuring principle adopted offers high precision and low pressure losses. A complete range of models is designed to satisfy all flow rate requirements. Easy interfacing with control systems makes these pulse meters the ideal solution for equipping fuel delivery pumps for private use in stationary lubricant transfer/delivery systems, as meters for tank filling arms, for control of burner or power unit fuel consumption and other industrial applications requiring fluid delivery control.

Performance

. Precision ± 0.5 % in flow rate range after calibration
. Repeatability 0.2%
. Pressure loss < 0.5 bars (7 psi) at max flow rate

 


K200g

K200g pdf  Technical Specs
K200g pdf  Catalogue Page
 


K200 Grease Meter     Suitable for Transferring GREASE

The flow-rate of grease nozzles depends on the specific working conditions:
. resistance to the entry of new grease, which depends on many factors (conduit diameter, working temperature, possible clogging, etc.); M . pump efficiency.MM Measuring the actual amount of grease only according to the time required for dispensing, may result in approximation errors both by defect or by excess. Thanks to the K200 Meter the exact amount of grease dispensed by the nozzle is no longer measured according to an empirically method, but can be accurately determined and displayed on a LCD. Thanks to its compact size and low weight GREASTER can replace normal grease dispensers, also offering the following advantages:
. it guarantees the correct and exact execution of the greasing operation by displaying the resettable batch total dispensed;
. it stores grease consumption by reckoning and displaying the cumulative total amount dispensed.

Performances

. Operating pressure: (max) 550 bar.
. Burst pressure: (min) 1600 bar.
. Metering accuracy: ± 3%.

 


K400

K400 Specs  Technical Specs
K400 Pdf  Catalogue Page
 


K400     Suitable for Transferring DIESELSuitable for Transferring OILSuitable for Transferring WINDSCREEN fluid

Oval gear meter

The electronic oval gear meters for product delivery control and measurement are used in the private distribution of low, medium and high viscosity fluids such as fuel, lubrication oil and other special fluids compatible with the construction materials. The oval gear measuring principle adopted offers high precision and low pressure losses together with a compact lightweight design and easy installation. An electronic card with microprocessor permits control of the display and calibration of the meter. A complete range of models is designed to satisfy all flow rate requirements. Ease of use, compactness and the independent battery power supply make these products suitable for installation in both stationary systems on fluid transfer and distribution lines and in mobile applications as an accessory for delivery valves and guns and for all other industrial applications that require fluid delivery control.

Performance

. Precision ± 0.5 % in flow rate range after calibration
. Repeatibility 0.2%
. Pressure loss < 0.5 bars (7 psi) at max flow rate

 


K600n

K600n Specs  Technical Specs
K600n PDF  Catalogue Page
 


K600 - new     Suitable for Transferring DIESELSuitable for Transferring OILSuitable for Transferring RAPS OILSuitable for Transferring WINDSCREEN fluid

Oval gear meter

The electronic oval gear meters for product delivery control and measurement are used in the private distribution of low, medium and high viscosity fluids such as fuel, lubrication oil and other special fluids compatible with the construction materials. The oval gear measuring principle adopted offers high precision and low pressure losses together with a compact lightweight design and easy installation. An electronic card with microprocessor permits control of the display and calibration of the meter. A complete range of models is designed to satisfy all flow rate requirements. Ease of use, compactness and the independent battery power supply make these products suitable for installation in both stationary systems on fluid transfer and distribution lines and in mobile applications as an accessory for delivery valves and guns and for all other industrial applications that require fluid delivery control.

Performance

. Precision ± 0.5 % in flow rate range after calibration
. Repeatibility 0.2%
. Pressure loss < 0.5 bars (7 psi) at max flow rate

 


K600np

K600np Specs  Technical Specs
K600np PDF  Catalogue Page
 


K600 Pulse - new     Suitable for Transferring DIESELSuitable for Transferring OILSuitable for Transferring RAPS OILSuitable for Transferring WINDSCREEN fluid

Oval gear pulse meter

The oval gear pulse meters are designed to meet a wide range of product delivery measuring requirements in the private distribution of fuel, lubricant and low, medium and high viscosity liquids. The oval gear measuring principle adopted offers high precision and low pressure losses. A complete range of models is designed to satisfy all flow rate requirements. Easy interfacing with control systems makes these pulse meters the ideal solution for equipping fuel delivery pumps for private use in stationary lubricant transfer/delivery systems, as meters for tank filling arms, for control of burner or power unit fuel consumption and other industrial applications requiring fluid delivery control.

Performance

. Precision ± 0.5 % in flow rate range after calibration
. Repeatability 0.2%
. Pressure loss < 0.5 bars (7 psi) at max flow rate

 


K600

K600 Specs  Technical Specs
K600 Pdf  Catalogue Page
 


K600     Suitable for Transferring DIESELSuitable for Transferring WINDSCREEN fluid

Oval gear meter

The electronic oval gear meters for product delivery control and measurement are used in the private distribution of low, medium and high viscosity fluids such as fuel, lubrication oil and other special fluids compatible with the construction materials. The oval gear measuring principle adopted offers high precision and low pressure losses together with a compact lightweight design and easy installation. An electronic card with microprocessor permits control of the display and calibration of the meter. A complete range of models is designed to satisfy all flow rate requirements. Ease of use, compactness and the independent battery power supply make these products suitable for installation in both stationary systems on fluid transfer and distribution lines and in mobile applications as an accessory for delivery valves and guns and for all other industrial applications that require fluid delivery control.

Performance

. Precision ± 0.5 % in flow rate range after calibration
. Repeatibility 0.2%
. Pressure loss < 0.5 bars (7 psi) at max flow rate

 


K600p

K600p Specs  Technical Specs
K600p PDFs  Catalogue Page
 


K600 Pulse     Suitable for Transferring DIESELSuitable for Transferring WINDSCREEN fluid

Oval gear pulse meter

The oval gear pulse meters are designed to meet a wide range of product delivery measuring requirements in the private distribution of fuel, lubricant and low, medium and high viscosity liquids. The oval gear measuring principle adopted offers high precision and low pressure losses. A complete range of models is designed to satisfy all flow rate requirements. Easy interfacing with control systems makes these pulse meters the ideal solution for equipping fuel delivery pumps for private use in stationary lubricant transfer/delivery systems, as meters for tank filling arms, for control of burner or power unit fuel consumption and other industrial applications requiring fluid delivery control.

Performance

. Precision ± 0.5 % in flow rate range after calibration
. Repeatability 0.2%
. Pressure loss < 0.5 bars (7 psi) at max flow rate

 


K700

K700 Specs  Technical Specs
K700 Pdf  Catalogue Page
 


K700 Pulse     Suitable for Transferring DIESELSuitable for Transferring WINDSCREEN fluid

Oval gear pulse meter

The oval gear pulse meters are designed to meet a wide range of product delivery measuring requirements in the private distribution of fuel, lubricant and low, medium and high viscosity liquids. The oval gear measuring principle adopted offers high precision and low pressure losses. A complete range of models is designed to satisfy all flow rate requirements. Easy interfacing with control systems makes these pulse meters the ideal solution for equipping fuel delivery pumps for private use in stationary lubricant transfer/delivery systems, as meters for tank filling arms, for control of burner or power unit fuel consumption and other industrial applications requiring fluid delivery control.

Performance

. Precision ± 0.5 % in flow rate range after calibration
. Repeatability 0.2%
. Pressure loss < 0.5 bars (7 psi) at max flow rate

 


K900

K900 Specs  Technical Specs
K900 Pdf  Catalogue Page
 


K900 Pulse     Suitable for Transferring DIESELSuitable for Transferring WINDSCREEN fluid

Oval gear pulse meter

The oval gear pulse meters are designed to meet a wide range of product delivery measuring requirements in the private distribution of fuel, lubricant and low, medium and high viscosity liquids. The oval gear measuring principle adopted offers high precision and low pressure losses. A complete range of models is designed to satisfy all flow rate requirements. Easy interfacing with control systems makes these pulse meters the ideal solution for equipping fuel delivery pumps for private use in stationary lubricant transfer/delivery systems, as meters for tank filling arms, for control of burner or power unit fuel consumption and other industrial applications requiring fluid delivery control.

Performance

. Precision ± 0.5 % in flow rate range after calibration
. Repeatability 0.2%
. Pressure loss < 0.5 bars (7 psi) at max flow rate

 


Remdisp

Remdisp specs  Technical Specs
Remdisp Pdf  Catalogue Page
 


Remote Display     Suitable for Transferring DIESELSuitable for Transferring OILSuitable for Transferring RAPS OILSuitable for Transferring UREASuitable for Transferring WINDSCREEN fluid

Designed and realised to be used with the range of pulse meters. Remote installation is provided by simply connecting 2 wires. A large screen simultaneously displays the quantity delivered and the non resettable total. The Remote Display also comes with software applications for calibrating flow metres. It is available both as a basic display device and as a pulse emitter. It is indispensable when the receiver only recognises discrete quantities of pulses. The remote display is the ideal addition to our series of pulse meters wherever display and reading of the quantities delivered are indispensable, not directly at the point of installation of the flow meters, but over a distance. With their easy interfacing management systems, pulse transmitter models connected to Remote Display extend the field of application of pulse meters.

Specification

. 8 digits resettable total available.
. Resettable total available.
. 8 digits non resettable total.
. 5 digits partial.
. Flow rate.
. Possibility to set unit of measure.
. Possibility to set puls out.
. Calibration.
. Low battery icon.

 


GPV

GPV Specs  Technical Specs
GPV PDF  Catalogue Page
 


GPV Pulse Meter      Suitable for Transferring OILSuitable for Transferring WINDSCREEN fluid

Pulse / valve unit

This component is for installation along the supply lines feeding the pumps in a centralised oil (or other fluid) distribution system. It combines the functions of an on-off valve with those of a flow-meter. This unit simplifies the realisation of a refuelling system because with a single hydraulic coupling and an electric connection you can install all the components needed to regulate the flow of fluids.

Performance Specifications

. Power supply: 24 V AC, 12 V DC, 24 V DC.
. Flow-rate (range): 2 ÷ 30 l/min (0,5 ÷ 7,9 gal/min).
. Viscosity (range): 9 ÷ 5000 cst.
. Max operating pressure: 70 bar (994 psi).
. Bursting pressure: 140 bar (1880 psi).
. Head loss: 4.8 bar (16 l/min with SAE W80/20° oil).
. Accuracy: ± 0.5% of flow range after calibration.
. Operating temperature (range): -5°C ÷ 40°C.
. Humidity: 10% ÷ 90% (max).
. Filter mesh: 150 microns
. Compatible fluids: oil, antifreeze.

 